InstaSprink Design · BS 9251:2021

Residential sprinkler design, from floor plan to finished drawings.

Lay out BS 9251:2021 sprinkler systems in your web browser. Heads placed and checked as you go, pipework laid out for you, the whole system shown in realistic 3D, and drawings and reports ready to issue.

  • Category 1 and 2
  • Realistic 3D view
  • Preliminary hydraulics
  • Nothing to install
  • PC, Mac and tablet

Download the InstaSprink Design brochure PDF · 9 pages · 5.5 MB

Already have an account? Sign in at app.instasprink.com

app.instasprink.com
InstaSprink Design: a ground floor plan with heads, coverage and pipework

Overview

Design faster. Check as you go. Issue with confidence.

InstaSprink Design takes a residential sprinkler system through seven clear steps, from the architect's plans to a full set of drawings and a preliminary hydraulic report. It does the repetitive work — placing and dimensioning heads, routing the pipework, finding the operating heads, drawing the system in 3D and filling in the title block — so your time goes on the design decisions.

Start from any plan

Drop in a PDF, PNG or JPG. Set the scale from one dimension and line the floors up.

Heads placed for you

Mark out a room and the heads are placed, spaced and dimensioned to the head's listed coverage.

Live coverage checks

Spacings, wall distances and uncovered areas show in red the moment anything is out.

Pipework laid out

Auto pipe runs a square 25 mm main and 20 mm branches to every head, with another route a click away.

See it in realistic 3D

Every floor, riser, branch and head, with the tank and pump set in place. Turn it, check it, put it on the drawing.

Preliminary hydraulics

Operating heads found and every combination checked against the supply, ready to confirm in your calculation software.

1PlansUpload the drawings for each floor
2ScaleSet the scale and line the floors up
3HeadsMark the rooms, heads placed
4PipeworkAuto pipe, risers and 3D check
5SupplyMains, boosted, or tank and pump
6HydraulicsMHU, densities and supply check
7DrawingsSheets, 3D view, report and materials
7guided steps, start to finish
A1 / A3drawing sheets as one PDF
1 clickfrom the plan to the 3D view
12

Plans and scale

Start from the plans you already have

Drop each floor's plan into the tool. A PDF straight from CAD works best, or use a PNG or JPG. Click both ends of a dimension you can read to set the scale, then click one fixed point on each floor so risers land in the same place on every level.

  • Multi-page PDFs and drawings with several floors on one sheet
  • Floors lined up from one reference point, so a riser drawn on one floor lands in the same place on every other
  • Revised drawings drop straight in. Your design and its scale carry over, the old drawing shows in red over the new one, and Line it up fixes any shift
  • Measure and Area tools for any distance, area or perimeter on the plan
app.instasprink.com
Plans step: each floor has its own plan
Plans. Each floor has its own plan. Crop to the part you need, or mark several floors on one sheet.
Scale and alignment panel
Scale and alignment, set from a real dimension, not a printed scale bar.
Area tool showing 16.40 square metres and perimeter
Area. Drag a box or click round the corners: area and perimeter show on the plan.
3

Sprinkler heads

Mark a room. The heads place themselves.

Drag a box for a rectangular room, or click round the corners of any other shape. Live dimensions and alignment guides keep the outline square. Close it and the heads are placed at the right spacings, with every head-to-head and head-to-wall dimension drawn on.

  • Head library of Rapidrop, Viking and Victaulic pendent and sidewall heads, with each coverage setting. Add your own to the company library
  • Drag a head too far and another of the same kind comes in to cover the gap. Drag it back and it goes again
  • Permitted exceptions under BS 9251:2021, such as small bathrooms and cupboards, marked and listed
  • Open rooms between floors, such as a hall and landing, linked as one fire compartment
  • Sloping ceilings, one slope or two to a ridge, with heads at their true heights
Tracing a room outline with live dimension
Tracing a room. Live dimensions and the in-line guide keep the outline true.
Heads placed and dimensioned in every room
Heads placed, spaced, dimensioned and labelled; WC and store marked as permitted exceptions.
Choosing the make, head and coverage setting
Pick the make, head and coverage setting. Its limits are spelt out in plain terms, and every head on the plan is checked against them as you work.

Change a head and it tells you. Swap to a head that covers less and what's no longer covered shows in red. One click re-places the room's heads, and pipes them in again if they were piped.

4

Pipework and risers

Pipework, laid out for you

Auto pipe works out the shortest square network from the riser to every head: a 25 mm main down the hall or landing and 20 mm branches to single heads. Keep it, ask for another route, or draw your own — runs stay at 90° and every tee and elbow is counted.

  • Heads are never the corner of a run. Every head sits in line on a tee or at the end of a run, the way an installer would fit it
  • Risers carry the pipework between floors, with the rise drawn and counted
  • Low-level runs with the drops down the wall put in for you, and floor zone valves for larger buildings
  • Sized as you choose: a 25 mm main with 20 mm to single heads, or all in 25 mm
  • Every fitting counted — tees, elbows, reducers and head adaptors — carried through to the materials list
app.instasprink.com
Proposed pipework highlighted in blue with lengths by size
Proposed pipework, highlighted with its lengths by size: keep it, suggest another route, or remove it.

Realistic 3D view

See the whole system before anyone picks up a pipe cutter

One click turns the plan into a 3D view of the installation: every floor in place, the riser climbing between them, each branch in its true size and colour, every head on its drop, and the tank and pump set where they will go.

3D view of a two-storey house with tank and pump set
A two-storey house with a tank and pump. 25 mm main in red, 20 mm branches in blue, each head on its drop, the fire pump set and the 1,487-litre tank. This view goes on the drawing sheet and downloads as its own PDF.

Floors on or off

Views from any side, so a riser or a congested corner can be looked at on its own.

Click to find it

Hover to name any head or pipe; click it and the plan jumps to it.

Nothing to model

Built from the design you've already drawn — tank and pump drawn to size — so it's always up to date.

56

Supply and preliminary hydraulics

Preliminary hydraulics, as you design

Choose how the system is fed: straight from the mains, boosted mains, or a dedicated tank and pump. Run the preliminary calculation and the operating heads are worked out for you, every combination is checked against the supply, and the result shows what the system needs and how much is to spare.

  • Mains: enter the flow test and the valve set; the supply curve is drawn for you
  • Tank and pump: fire pump sets and their curves built in, with the tank sized and checked, including proven infill
  • MHU and MHF found; every head checked for flow, pressure and design density, Category 1 or 2
  • Fitting losses to BS 9251:2021 Table B.6, with each pipe's calculation shown
  • Balance heads: swap to lower-flow heads where coverage allows, without making the MHU harder
  • Export for your hydraulic calculation software, with the pipe data file to match

For assistance with the design, not the final word. The built-in hydraulics are preliminary: they help you arrive at a layout that works. The calculation must be confirmed in your preferred hydraulic calculation software before issue, and the tool exports the system ready for that.

Result: most hydraulically unfavourable heads 107.4 L/min at 1.98 bar
The result: the MHU, its flow and pressure, and the densities met.
Demand plotted against the mains supply curve
Supply check — the demand against the mains curve.
Flow path to the operating heads shown in yellow
Flow path on the plan. Click any combination and the plan jumps to it, with the flow path in yellow, including up the riser.
Table of all operating head combinations
Every combination, side by side: flow, pressure, lowest density against the least allowed, and spare pressure.
7

Drawings and reports

Drawings and reports, ready to issue

Each floor goes on its own A1 or A3 sheet at a true scale, with your company's title block and logo filled in from the project, and the details an approving body expects alongside the plan. Download the set as one PDF, with the preliminary hydraulic report and an estimated materials list.

  • Sectional riser detail, tank effective capacity and head data table
  • CPVC bracing and clips, MHU and MHF heads, legend and design data
  • Notes and calculation summary, 3D pipework view, pump set and curve
  • Title block and revisions, with an issue status on every sheet
PreliminaryFor ApprovalFor ConstructionAs Installed

For Construction and As Installed open once InstaSprink has verified your company's design competency.

An A1 drawing sheet with plan, details, 3D view and title block
A drawing sheet with the riser detail, tank capacity, head data, bracing, legend, notes, 3D view, pump curve and title block.
Preliminary report pageCombinations and MHU calculation sheetMaterials list

Preliminary report: layouts, riser detail and schedules · every combination and the MHU calculation sheet · materials list.

Built for the way you work

Nothing to install. Your whole team on one login.

Made for touch as well as a mouse, so the same project opens on a tablet on site or a big screen in the office, with every change saved to the company account.

Runs in your browser

On a PC, Mac or tablet, or installed as an app. Projects save to your company account, ready to pick up anywhere.

Seats for your designers

Named seats for the people who design, and free view-only users who can open, check and download.

Help where you need it

Find a feature (Ctrl+K) answers “how do I…?” and takes you to the button. Message us from inside the tool.

Design competency

Verified companies issue drawings For Construction and As Installed.

Straightforward pricing

£99 per seat / month if you sign up by 30 April 2027, fixed for 12 months (standard price £149). Or £35 per design. Estimate included free. See pricing

Your branding

Your logo, address and confidentiality text on every drawing, filled in once for the whole company.

app.instasprink.com
InstaSprink Design on a tablet

Try it on your next project

Start your free 14-day trial of InstaSprink Design

Create an account at app.instasprink.com and start a full trial, so you can run a real job through it from plans to drawings.

Sign up or sign in
app.instasprink.com
Web
instasprink.com

InstaSprink supplies design software only and accepts no responsibility for any design: head positions, pipe layouts and hydraulic calculations produced automatically are preliminary and are suggestions for a competent designer to check and verify, with the hydraulic calculation confirmed in the designer's preferred hydraulic calculation software before issue. Screens show sample projects. Rapidrop, Viking and Victaulic are trademarks of their respective owners.